Customization: | Available |
---|---|
Type: | Basic Diesel Generator |
Installation Method: | Fixed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ENGINE DATA | ||||||
Manufacturer/Model: | DCEC Diesel Engine 6CTA8.3-G2,4-cycle | |||||
Air Intake System: | Turbo,Water/Air Cooling | |||||
Fuel System: | PB type fuel pump | |||||
Cylinder Arrangement: | 6 in line | |||||
Displacement: | 8.3L | |||||
Bore and Stroke: | 114×135(mm) | |||||
Compression Ratio: | 17.0:1 | |||||
Rated RPM: | 1500rpm | |||||
Max.Standby Power at Rated RPM: | 180KW /244HP | |||||
Governor Type: | Electronic | |||||
Exhaust System | ||||||
Exhaust Gas Flow: | 34.7m3/min | |||||
Exhaust Temperature: | 570 degree | |||||
Max Back Pressure: | 10kPa | |||||
Air Intake System | ||||||
Max Intake Restriction: | 6kPa | |||||
Buring Capacity: | 12.4m3/min | |||||
Intake Flow: | 238m3/min | |||||
Fuel System | ||||||
100%(Prime Power) Load: | 215 g/Kw.h | |||||
75%(Prime Power) Load: | 211 g/Kw.h | |||||
75%(Prime Power) Load: | 216 g/Kw.h | |||||
Oil System | ||||||
Total Oil Capacity: | 27.6L | |||||
Oil Consumption: | ≤ 4g/kwh | |||||
Engine Oil Tank Capacity: | 24L | |||||
Oil Pressure at Rated RPM: | 276-414kPa | |||||
Cooling System | ||||||
Total Coolant Capacity: | 34L | |||||
Thermostat: | 82-95 | |||||
Max Water Temperature: | 104 | |||||
ALTERNATOR SPECIFICATION | ||||||
GENERAL DATA | ||||||
Compliance with GB755,BS5000,VDE0530,NEMAMG1-22,IED34-1,CSA22.2 and AS 1359 standards. | ||||||
Alternator Data | ||||||
Manufacturer: | Leroy somer / Engga / Marathon / Kaijieli / Dingol | |||||
Number of Phase: | 3 | |||||
Connecting Type: | 3 Phase and 4 Wires,"Y" type connecting | |||||
Number of Bearing: | 1 | |||||
Power Factor: | 0.8 | |||||
Protection Grade: | IP23 | |||||
Altitude: | ≤ 1000m | |||||
Exciter Type: | Brushless,self-exciting | |||||
Insulation Class,Temperature Rise: | H/H | |||||
Telephone Influence Factor(TIF): | < 50 | |||||
THF: | < 2% | |||||
Voltage Regulation,Steady State: | ≤ ±1% | |||||
Alternator Capacity: | 150KVA | |||||
Alternator Efficiencies: | 92.20% | |||||
Air Cooling Flow: | 0.37m3/s | |||||
GENERATING SET DATA | ||||||
Voltage Regulation: | ≥ ± 5% | |||||
Voltage Regulation,stead state: | ≤ ± 1% | |||||
Sudden Voltage Warp(100% Sudden Reduce): | ≤ +25% | |||||
Sudden Voltage Warp( Sudden Increase): | ≤ -20% | |||||
Voltage Stable Time(100% Sudden Reduce): | ≤ 6S | |||||
Voltage Stable Time(Sudden Increase): | ≤ 6S | |||||
Frequency Regulation,Stead State: | ≤5 % | |||||
Frequency Waving: | ≤1.5 % | |||||
Sudden Frequency Warp(100% Sudden Reduce): | ≤ +12% | |||||
Sudden Frequency Warp(Sudden Increase): | ≤ -10% | |||||
Frequency Recovery Time(100% Sudden Reduce): | ≤ 5S | |||||
Frequency Recovery Time(Sudden Increase): | ≤ 5S | |||||
Options |